{"product_id":"victron-battery-balancer","title":"Victron Battery Balancer","description":"\u003ch2 data-section-id=\"1og5t7q\" data-start=\"143\" data-end=\"158\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"146\" data-end=\"158\"\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"160\" data-end=\"227\"\u003eBattery Balancer – Protect and Extend the Life of Your Battery Bank\u003c\/p\u003e\n\u003cp data-start=\"229\" data-end=\"515\"\u003eIn multi-battery systems, small differences between batteries can lead to major long-term damage. When batteries are connected in series or parallel, even a slight variation in internal leakage or state of charge can cause some batteries to be overcharged while others are undercharged.\u003c\/p\u003e\n\u003cp data-start=\"517\" data-end=\"544\"\u003eOver time, this results in:\u003c\/p\u003e\n\u003cul data-start=\"545\" data-end=\"730\"\u003e\n\u003cli data-section-id=\"zw52xb\" data-start=\"545\" data-end=\"611\"\u003eOvercharging and excessive gassing in higher-voltage batteries\u003c\/li\u003e\n\u003cli data-section-id=\"zsqqxn\" data-start=\"612\" data-end=\"671\"\u003eUndercharging and sulphation in lower-voltage batteries\u003c\/li\u003e\n\u003cli data-section-id=\"k9drk3\" data-start=\"672\" data-end=\"730\"\u003eReduced performance and shortened overall battery life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"732\" data-end=\"855\"\u003eThis issue is especially common in 24V and 48V systems, and even more likely when adding new batteries to an existing bank.\u003c\/p\u003e\n\u003cp data-start=\"857\" data-end=\"1089\"\u003eThe Battery Balancer solves this by actively equalizing the state of charge between batteries. By keeping all batteries aligned, it helps prevent damage, improves system performance, and extends the usable life of your battery bank.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1649c9u\" data-start=\"1096\" data-end=\"1111\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1099\" data-end=\"1111\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1113\" data-end=\"1296\"\u003eActive Battery Balancing\u003cbr data-start=\"1137\" data-end=\"1140\"\u003eContinuously monitors and balances two series-connected 12V batteries (or multiple parallel strings), ensuring consistent state of charge across the system.\u003c\/p\u003e\n\u003cp data-start=\"1298\" data-end=\"1438\"\u003eAutomatic Operation\u003cbr data-start=\"1317\" data-end=\"1320\"\u003eActivates when system voltage exceeds 27.3V and automatically begins correcting voltage differences between batteries.\u003c\/p\u003e\n\u003cp data-start=\"1440\" data-end=\"1588\"\u003ePrevents Battery Damage\u003cbr data-start=\"1463\" data-end=\"1466\"\u003eReduces risk of overcharging, undercharging, sulphation, and excessive gassing—common causes of premature battery failure.\u003c\/p\u003e\n\u003cp data-start=\"1590\" data-end=\"1722\"\u003eScalable for Larger Systems\u003cbr data-start=\"1617\" data-end=\"1620\"\u003eMultiple units can be used together. A 48V battery bank can be balanced using three Battery Balancers.\u003c\/p\u003e\n\u003cp data-start=\"1724\" data-end=\"1783\"\u003eLED Status Indicators\u003cbr data-start=\"1745\" data-end=\"1748\"\u003eProvides clear system visibility:\u003c\/p\u003e\n\u003cul data-start=\"1784\" data-end=\"1944\"\u003e\n\u003cli data-section-id=\"1vt64dn\" data-start=\"1784\" data-end=\"1834\"\u003eGreen: Active (system voltage above threshold)\u003c\/li\u003e\n\u003cli data-section-id=\"7jku2b\" data-start=\"1835\" data-end=\"1893\"\u003eOrange: Balancing active on upper or lower battery leg\u003c\/li\u003e\n\u003cli data-section-id=\"kaxuhh\" data-start=\"1894\" data-end=\"1944\"\u003eRed: Alarm condition for significant imbalance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1946\" data-end=\"2089\"\u003eIntegrated Alarm Relay\u003cbr data-start=\"1968\" data-end=\"1971\"\u003eNormally open relay closes during alarm conditions, allowing integration with external monitoring or shutdown systems.\u003c\/p\u003e\n\u003cp data-start=\"2091\" data-end=\"2242\"\u003eManual Alarm Reset\u003cbr data-start=\"2109\" data-end=\"2112\"\u003eIncludes terminals for an external push-button reset. System automatically resumes monitoring after alarm conditions are resolved.\u003c\/p\u003e\n\u003cp data-start=\"2244\" data-end=\"2407\"\u003eCompatible with Midpoint Monitoring\u003cbr data-start=\"2279\" data-end=\"2282\"\u003eWorks alongside advanced monitoring systems (such as midpoint monitoring) for deeper insight into battery health and balance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"q11yyz\" data-start=\"2414\" data-end=\"2435\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2417\" data-end=\"2435\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2437\" data-end=\"2538\"\u003eSystem Compatibility:\u003cbr data-start=\"2458\" data-end=\"2461\"\u003eDesigned for 24V and 48V battery banks using series\/parallel configurations\u003c\/p\u003e\n\u003cp data-start=\"2540\" data-end=\"2639\"\u003eBalancing Function:\u003cbr data-start=\"2559\" data-end=\"2562\"\u003eBalances two 12V batteries connected in series or multiple parallel strings\u003c\/p\u003e\n\u003cp data-start=\"2641\" data-end=\"2707\"\u003eActivation Voltage:\u003cbr data-start=\"2660\" data-end=\"2663\"\u003eTurns on when system voltage exceeds 27.3V\u003c\/p\u003e\n\u003cp data-start=\"2709\" data-end=\"2776\"\u003eBalancing Current:\u003cbr data-start=\"2727\" data-end=\"2730\"\u003eUp to 0.7A drawn from higher-voltage battery\u003c\/p\u003e\n\u003cp data-start=\"2778\" data-end=\"2978\"\u003eDeviation Thresholds:\u003cbr data-start=\"2799\" data-end=\"2802\"\u003eBalancing active when deviation exceeds 0.1V\u003cbr data-start=\"2846\" data-end=\"2849\"\u003eAlarm triggered when deviation exceeds 0.2V\u003cbr data-start=\"2892\" data-end=\"2895\"\u003eAlarm resets when deviation drops below 0.14V or system voltage drops below 26.6V\u003c\/p\u003e\n\u003cp data-start=\"2980\" data-end=\"3098\"\u003eLED Indicators:\u003cbr data-start=\"2995\" data-end=\"2998\"\u003eGreen – System active\u003cbr data-start=\"3019\" data-end=\"3022\"\u003eOrange – Balancing active (upper or lower battery)\u003cbr data-start=\"3072\" data-end=\"3075\"\u003eRed – Alarm condition\u003c\/p\u003e\n\u003cp data-start=\"3100\" data-end=\"3171\"\u003eAlarm Relay:\u003cbr data-start=\"3112\" data-end=\"3115\"\u003eNormally open relay that closes during alarm condition\u003c\/p\u003e\n\u003cp data-start=\"3173\" data-end=\"3230\"\u003eAlarm Reset:\u003cbr data-start=\"3185\" data-end=\"3188\"\u003eExternal reset via push-button terminals\u003c\/p\u003e\n\u003cp data-start=\"3232\" data-end=\"3348\"\u003eScalability:\u003cbr data-start=\"3244\" data-end=\"3247\"\u003eMultiple units can be installed in parallel\u003cbr data-start=\"3290\" data-end=\"3293\"\u003eThree units required for balancing a 48V battery bank\u003c\/p\u003e\n\u003cp data-start=\"3350\" data-end=\"3504\"\u003eApplication:\u003cbr data-start=\"3362\" data-end=\"3365\"\u003eRV electrical systems\u003cbr data-start=\"3386\" data-end=\"3389\"\u003eOff-grid solar battery banks\u003cbr data-start=\"3417\" data-end=\"3420\"\u003eBackup power systems\u003cbr data-start=\"3440\" data-end=\"3443\"\u003eAny multi-battery configuration requiring balanced charging\u003c\/p\u003e","brand":"TechnoRV","offers":[{"title":"Default Title","offer_id":48329220849884,"sku":null,"price":69.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0649\/6124\/9500\/files\/250_897_20180705170552.png?v=1774310206","url":"https:\/\/technorv.com\/en-ca\/products\/victron-battery-balancer","provider":"TechnoRV","version":"1.0","type":"link"}